Register a Room Comfort Sensor

This topic describes how to register your Room Comfort Sensors to Yeastar Workplace so the devices can be associated with the room resources in your system.

Requirements

Yeastar Workplace plan: Pro Plan

Prerequisites

  • You have added room resources in Yeastar Workplace.
  • You have set up one of the following devices:
    • Yeastar Room Display DS7510 with the hardware version x.x.x.x-r3 or later
      Note: To view the hardware version, go to Device List and click of the desired Room Display, then go to Basic Info > Hardware Version.

Procedure

  1. Log in to Yeastar Workplace management portal, go to Device List.
  2. Click Add, and configure the following information in the pop-up window.
    Item Description
    Registration Code/ SN

    Enter the Serial Number (SN) of this device.

    If the SN is correct, the system automatically detects the device type.
    Note: You can collect the SN on the back panel of the device.
    Device Name Specify a name to help you identify this device.
    Associated Gateway Select a gateway or Room Display DS7510 for transmitting data between Yeastar Workplace and the device.
    Tip: Refer to the following suggestions for optimal data transmission quality:
    • If you want to associate the device with a gateway, select a gateway that is installed on the same floor as the device.
    • If you want to associate the device with a Room Display DS7510, select the one that is located within 288 m3 (12*8*3 m) range of the device, and do NOT associate more than 10 devices with the same Room Display DS7510.
    Bind to Select a room resource to associate with this device.
  3. Click OK.

  4. Mark the device to remind you where it will be installed.

    For example, attach a label of its associated meeting room on the back of the device.

  5. Repeat Step 2 ~ Step 4 for all the devices that need to be set up.

Result

You have registered Room Comfort Sensors to Yeastar Workplace. After the devices are powered on, they will be activated and connected to Yeastar Workplace automatically.

What to do next

Install Room Comfort Sensor AM307