Connect Yeastar P-Series PBX System and Yeastar TG400 Gateway
This topic describes how to connect Yeastar P-Series PBX System and Yeastar TG400 gateway, so as to extend GSM/3G/4G trunks on the PBX.
Procedure
Step 1. Create a SIP peer trunk on Yeastar PBX system
- Log in to PBX web portal, go to Add. , click
- Configure the trunk settings.
- Name: Enter a name to help you identify it. For example, TG400.
- Trunk Status: Select Enabled.
- Select ITSP Template: Select General.
- Trunk Type: Select Peer Trunk.
- Transport: Select UDP.
- Hostname/IP: Enter the IP address of Yeastar TG400 gateway. In this example, enter 192.168.6.200.
- Port: Enter the SIP port of Yeastar TG400 gateway. In this example, enter the default port 5060.
- Domain: Enter the IP address of Yeastar TG400 gateway. In this example, enter 192.168.6.200.
- Click Save and Apply.
Step 2. Create a SIP peer trunk on Yeastar TG400 gateway
- Log in to gateway web interface, go to Add VoIP Trunk. , click
- In the pop-up window, configure the trunk settings:
- Trunk Type: Select Peer Trunk.
- Type: Select SIP.
- Provider Name: Enter a name to help you identify it.
- Hostname/IP: Enter the IP address of Yeastar PBX system and the SIP port. In this example, enter 192.168.6.124 and the default SIP port 5060.
- Click Save and Apply Changes.
Result
- On PBX web portal ( ), the trunk status displays .
- On TG400 gateway web interface (OK". ), the trunk status displays "
It is concluded that Yeastar PBX system is connected to Yeastar TG400 gateway; 4 GSM trunks are extended on Yeastar PBX system.
What to do next
- To make outbound calls through the extended GSM trunk, see Make Outbound Calls through a Designated GSM Trunk.
- To receive inbound calls through the extended GSM trunk, see Route Calls from Different Carriers to Different Destinations.